Secondary Containment Coatings

A containment area only matters on the day something leaks. On that day the coating is the part doing the holding. Columbia Industrial Coatings lines and coats secondary containment, from tank farm dikes and bunds to curbing, trenches and sumps, for plants and facilities across the Tri-Cities and the Pacific Northwest.

Secondary Containment Lining and Coating

Bare concrete is porous. It absorbs what spills onto it, cracks with temperature, and lets chemicals work into the slab and out the other side. A containment lining closes that path with a continuous, bonded surface that holds liquid long enough for it to be recovered.

Specified Against the Chemistry

There is no single best containment coating. A system that handles fuel all day may soften under a solvent, and one that resists an acid at room temperature can fail with the same acid hot. So the specification starts with what the area holds: the chemical, its concentration, its temperature and how long it would sit. Chemical resistant coatings are then chosen from the coating manufacturer's resistance data for that exposure, not from a general chart.

Coated storage and transfer equipment at an industrial facility
Coated industrial facility structure

Where Containment Fails

Rarely in the middle of the floor. Almost always at an edge: the joint between floor and wall, a pipe penetration through the curb, the lip of a sump, an expansion joint that was filled with the wrong material. We detail those areas first and treat them as the main job, because they are.

How the Work Runs

  1. Site walk to identify the stored chemicals and the condition of the concrete.
  2. System selected against the chemistry and the temperature.
  3. Concrete preparation by grinding or shot blasting, plus crack and joint repair.
  4. Detailing of joints, penetrations and sumps before the field coat goes down.
  5. Application to the specified thickness, then inspection and holiday testing where the specification calls for it.

Working Around a Running Site

Containment usually sits next to tanks that are in service. We section the work so storage can keep running, plan ventilation and access around the operation, and choose systems whose cure times fit the window you can give us.

Where We Do This Work

Containment is part of our wider industrial painting work. Fuel facilities, chemical storage, water and waste water treatment, food and juice processing, agriculture and power generation, across Richland, Kennewick, Pasco, West Richland and the wider Pacific Northwest.

Request a quote for your containment area.

Frequently Asked Questions

A continuous lining applied to the concrete or steel around stored liquids, such as dikes, bunds, curbing and sumps, so that a leak is held rather than absorbed into the ground.

It depends on what is stored, how concentrated it is and how hot it gets. We select the system from the coating manufacturer’s resistance data for that exact exposure.

Usually yes. We section the work so storage keeps running and plan ventilation and access around the operation.

Yes. Cracks and joints are repaired and detailed as part of preparation, because that is where containment leaks.